Fast and great quotations, informed advisers to help you choose the correct product that suits all your preferences, a short creation time, responsible top quality control and different services for paying and shipping affairs for Vickers Hardness Testing Machine, Ut Block, Metallographic Sample Grinding And Polishing Machine, Welcome any of your inquiries and concerns for our products, we look forward to establishing a long-term business relationship with you in the near future. contact us today.
Factory Free sample Thickness Measuring Gauge - TM510FNplus Coating thickness gauge – TMTeck Detail:

ery (2)

● 2 Measuring modes: continuous/single
● 2 Shutdown modes: manual/automatic
●Wide measuring range with 5 probes available (next page)
●Direct testing mode and block statistics mode (APPL/BATCH)
●Can connect with printer to out of statistical values
●Dataview to connect with PC with USB 2.0 port
●500 datas can be stored

Main features
Can use various probe (F400, F1, F1/90 °, F10, N1, N400, etc.) measurement;
Three calibration methods: one point calibration, two point calibration, the basic calibration;
Display resolution: 0.1 um (measuring range of less than 100 um)
1μ m (range greater than 100 u m)
Have five statistics, data storage 500
There are two working methods: direct ways and means of group
There are two measurements: continuous measurement and a single measurement
There are two shutdown: manual and automatic shutdown shutdown
Can be set Bound: The gauge of the measured value can be automatic alarm and a number of measurements available on the histogram value analysis;
Deleted features: the gross error and error settings can be deleted;
Printing: Print Measurement measurement, statistics, gauges, histogram
A music tone in the operation carried out at any time tips
A power supply under-voltage direct function
An error function
And printers, computer communications (communications software operating environment for the Window operating system) connectivity.

Technical Specifications:

Measuring range

 

0-1250µ with standard probe F1.N1 (10.000mm    max)
Probes available

 

5 probes available for F (ferrous: on steel/iron) and N (non-ferrous metals)
Tolerance

 

F1:±(1µ+3%H) N1.±(1.5µ+3% H)

H: actual thickness tested

Resolution Alphanumeric with 4 large digits
Operation language English
Standards DIN, ISO, ASTM,BS
Min. measuring area F1:(standard probe)
Min. curvature  radius convex:3mm, concave:50mm
Min. substrate

thickness

type F: 0.5mm, type N: 50mm
Calibration Zero and foil calibration
Statistics

 

Number of measurements, mean, standard deviation,

maximum and minimum of 3000readings

Data memory 500  measuring data
Limits Adjustable with acoustic alarm
Interface USB 2.0
Operating temperature 0-40℃
power supply AA size 1.5V
Dimensions 125*67*31mm (main unit)
Weight 345.g

Standard Delivery

·  Main unit 1
·  Probe F1 or N1 1
·  Calibration foils 5
·  Instruction manual 1
·   Cetificate 1
·  Warranty card 1
·  Carrying case 1
Communication cable 1
PC software Dataview 1

Optional accessories
●5 probes for different applications
●Calibration foils in various thickness

ery (1)

Type F probe:

Probe

F400

F5

F1

F1/90°

F10

Measuring Principle   Magnetic method
Measuring range(mm)

0400um

01250 um

010000

Min resolution(mm)

0.1

0.1

10

Tolerance One-point calibration (mm)

±(2%H+0.7)

±(2%H+1)

±(2%H+10)

Two-point calibration (mm) ±(1%H+0.7)

±((1%H+1)

±(1%H+10)

Minimum radius of curvature (convex) (mm)

1

1.5

1.5

flat

10

 Minimum measuring area(mm)

F3

F7

F7

F40

Minimum thickness of base material(mm)

0.2

0.5

0.5

2

Type N probe

Probe N400

N1

CN02

Measuring Principle

Eddy current method

 Measuring range (mm)

0400

01250

10200

 Min resolution(mm)

0.1

0.1

1

Tolerance  One-point calibration (mm)

±(2%H+0.7)

±(2%H+1.5)

±(2%H+1)

 Two-point calibration (mm) ±(1%H+0.7) ±1%H+1.5

——–

Minimum radius of curvature (convex) (mm)

1.5

3

flat

Minimum measuring area(mm)

F4

F5

F7

Minimum thickness of base material(mm)

0.3

0.3

0


Product detail pictures:

Factory Free sample Thickness Measuring Gauge - TM510FNplus Coating thickness gauge – TMTeck detail pictures


Related Product Guide:

We are experienced manufacturer. Wining the majority of the crucial certifications of its market for Factory Free sample Thickness Measuring Gauge - TM510FNplus Coating thickness gauge – TMTeck , The product will supply to all over the world, such as: Hamburg, Turkmenistan, Barbados, Many products fully conform to the most rigorous of international guidelines and with our first-rate delivery service you will have them delivered at any time and in any place. And because Kayo deals in the entire spectrum of protective equipment, our customers don't need to waste time shopping around.
  • Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By Eleanore from Malta - 2018.09.23 18:44
    Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
    5 Stars By Jack from Armenia - 2018.12.28 15:18
    Write your message here and send it to us