OEM China Oil Tank Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck
OEM China Oil Tank Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck Detail:
● 2 Measuring modes: continuous/single
● 2 Shutdown modes: manual/automatic
●Wide measuring range with 5 probes available (next page)
●Direct testing mode and block statistics mode (APPL/BATCH)
●Can connect with printer to out of statistical values
●Dataview to connect with PC with USB 2.0 port
●500 datas can be stored
Main features
Can use various probe (F400, F1, F1/90 °, F10, N1, N400, etc.) measurement;
Three calibration methods: one point calibration, two point calibration, the basic calibration;
Display resolution: 0.1 um (measuring range of less than 100 um)
1μ m (range greater than 100 u m)
Have five statistics, data storage 500
There are two working methods: direct ways and means of group
There are two measurements: continuous measurement and a single measurement
There are two shutdown: manual and automatic shutdown shutdown
Can be set Bound: The gauge of the measured value can be automatic alarm and a number of measurements available on the histogram value analysis;
Deleted features: the gross error and error settings can be deleted;
Printing: Print Measurement measurement, statistics, gauges, histogram
A music tone in the operation carried out at any time tips
A power supply under-voltage direct function
An error function
And printers, computer communications (communications software operating environment for the Window operating system) connectivity.
Technical Specifications:
Measuring range
|
0-1250µ with standard probe F1.N1 (10.000mm max) |
Probes available
|
5 probes available for F (ferrous: on steel/iron) and N (non-ferrous metals) |
Tolerance
|
F1:±(1µ+3%H) N1.±(1.5µ+3% H)
H: actual thickness tested |
Resolution | Alphanumeric with 4 large digits |
Operation language | English |
Standards | DIN, ISO, ASTM,BS |
Min. measuring area | F1:(standard probe) |
Min. curvature radius | convex:3mm, concave:50mm |
Min. substrate
thickness |
type F: 0.5mm, type N: 50mm |
Calibration | Zero and foil calibration |
Statistics
|
Number of measurements, mean, standard deviation,
maximum and minimum of 3000readings |
Data memory | 500 measuring data |
Limits | Adjustable with acoustic alarm |
Interface | USB 2.0 |
Operating temperature | 0-40℃ |
power supply | AA size 1.5V |
Dimensions | 125*67*31mm (main unit) |
Weight | 345.g |
Standard Delivery
· Main unit | 1 |
· Probe F1 or N1 | 1 |
· Calibration foils | 5 |
· Instruction manual | 1 |
· Cetificate | 1 |
· Warranty card | 1 |
· Carrying case | 1 |
Communication cable | 1 |
PC software Dataview | 1 |
Optional accessories
●5 probes for different applications
●Calibration foils in various thickness
Type F probe:
Probe |
F400 |
F5 |
F1 |
F1/90° |
F10 |
||
Measuring Principle | Magnetic method | ||||||
Measuring range(mm) |
0~400um |
0~1250 um |
0~10000 |
||||
Min resolution(mm) |
0.1 |
0.1 |
10 |
||||
Tolerance | One-point calibration (mm) |
±(2%H+0.7) |
±(2%H+1) |
±(2%H+10) |
|||
Two-point calibration (mm) | ±(1%H+0.7) |
±((1%H+1) |
±(1%H+10) |
||||
Minimum radius of curvature (convex) (mm) |
1 |
1.5 |
1.5 |
flat |
10 |
||
Minimum measuring area(mm) |
F3 |
|
F7 |
F7 |
F40 |
||
Minimum thickness of base material(mm) |
0.2 |
|
0.5 |
0.5 |
2 |
Type N probe
Probe | N400 |
N1 |
CN02 |
|
Measuring Principle |
Eddy current method |
|||
Measuring range (mm) |
0~400 |
0~1250 |
10~200 |
|
Min resolution(mm) |
0.1 |
0.1 |
1 |
|
Tolerance | One-point calibration (mm) |
±(2%H+0.7) |
±(2%H+1.5) |
±(2%H+1) |
Two-point calibration (mm) | ±(1%H+0.7) | ±(1%H+1.5) |
——– |
|
Minimum radius of curvature (convex) (mm) |
1.5 |
3 |
flat |
|
Minimum measuring area(mm) |
F4 |
F5 |
F7 |
|
Minimum thickness of base material(mm) |
0.3 |
0.3 |
0 |
Product detail pictures:
Related Product Guide:
We also provide item sourcing and flight consolidation solutions. We have now our very own manufacturing facility and sourcing place of work. We could provide you with nearly every kind of merchandise associated to our merchandise variety for OEM China Oil Tank Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck , The product will supply to all over the world, such as: France, Georgia, Swedish, With a team of experienced and knowledgeable personnel, our market covers South America, the USA, the Mid East, and North Africa. Many customers have become our friends after good cooperation with us. If you have the requirement for any of our products, please contact us now. We are looking forward to hearing from you soon.
By Cindy from New Orleans - 2017.08.28 16:02
Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
By Teresa from Costa rica - 2018.12.11 11:26