OEM Manufacturer Ultrasonic Calibration Blocks - Penetrant Testing Specimen Precision Star Tam Panel Ndt – TMTeck
OEM Manufacturer Ultrasonic Calibration Blocks - Penetrant Testing Specimen Precision Star Tam Panel Ndt – TMTeck Detail:
Penetrant testing test specimen
Model:TM-B3
All linear dimensions to the requirements of AS2083/2005, BS2704/1978/1983, where applicable. Heat treatment to the requirements of GB/T6394/2002. where practicable tolerances to (+/-0.1mm) unless otherwise stated. Treated to 920 degrees C for 30 minutes, water quenched, 650 degrees C for 3 hours, air cooled
Material standard:according to ISO 10474-3.1.B,JIS G 0415-3.1.B
Depth:100µm
Width target value:0.5µm
Test standard:ISO 3452-3:1998(E),JB/T6064
Model:TM-A5
All linear dimensions to the requirements of AS2083/2005, BS2704/1978/1983, where applicable. Heat treatment to the requirements of GB/T6394/2002. where practicable tolerances to (+/-0.1mm) unless otherwise stated. Treated to 920 degrees C for 30 minutes, water quenched, 650 degrees C for 3 hours, air cooled
Material standard:according to ISO 10474-3.1.B,JIS G 0415-3.1.B
Depth:100µm
Width target value:0.5µm
Test standard:ISO 3452-3:1998(E),JB/T6064
Model:TM-D
All linear dimensions to the requirements of AS2083/2005, BS2704/1978/1983, where applicable. Heat treatment to the requirements of GB/T6394/2002. where practicable tolerances to (+/-0.1mm) unless otherwise stated. Treated to 920 degrees C for 30 minutes, water quenched, 650 degrees C for 3 hours, air cooled
Material standard:according to ISO 10474-3.1.B,JIS G 0415-3.1.B
Depth:150µm
Width target value:0.5µm,1.0μ and 1.5μ
Test standard:ISO 3452-3:1998(E),JB/T6064
Model:TM-AB
Through the physical and chemical test type A block material for LY12 aluminum alloy for materials, the chemical components conform to the provisions of ASTM,GB/T3190
By means of a micrometer measurement block length is 76 + 0.1 ㎜, and the width fifty + / – 0.1 ㎜, thick and ± 1 ㎜. Cut along the length center evenly divided into two pieces, and in block A and B and unity Numbers, block length orientation and plate rolling direction. Milling, grinding the surface roughness after treatment for Ra = 1.2 u m – 2.5 u m.
Color: Visual its color is silvery white.
Oxidizing property :In -55 ℃ ~ 200 ℃ – store between three years not metamorphism, no oxidation,
Crack: In the same Numbers of the A and B block with dye penetrant inspection method measured random crack 3 μ m, 3 μ m ~ 5 μ m and more than 5 μ m open crack on one side not less than four, and there are two above width is not more than 3 μ m open crack. Block A and B on the surface crack distribution is similar.
ASTME165 standard
Product detail pictures:
Related Product Guide:
Our merchandise are commonly recognized and reliable by customers and can meet constantly developing economic and social desires for OEM Manufacturer Ultrasonic Calibration Blocks - Penetrant Testing Specimen Precision Star Tam Panel Ndt – TMTeck , The product will supply to all over the world, such as: Australia, Nicaragua, Lithuania, We insist on the principle of "Credit being primary, Customers being the king and Quality being the best", we are looking forward to the mutual cooperation with all friends at home and abroad and we will create a bright future of business.
By Doris from Singapore - 2018.11.02 11:11
Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
By David Eagleson from South Korea - 2017.10.27 12:12