Have a question? Give us a call: +8613911515082

OEM Supply Paint Coating Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Quality First,and Customer Supreme is our guideline to provide the best service to our customers.Nowadays, we are trying our best to become one of the best exporters in our field to meet customers more need for Wilson Hardness Test Blocks, Hardness Test Standard, Ultrasonic Testing Cables, Our company is working through the procedure principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a pleasant relationship with businessman from all around the earth.
OEM Supply Paint Coating Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck Detail:

ery (2)

● 2 Measuring modes: continuous/single
● 2 Shutdown modes: manual/automatic
●Wide measuring range with 5 probes available (next page)
●Direct testing mode and block statistics mode (APPL/BATCH)
●Can connect with printer to out of statistical values
●Dataview to connect with PC with USB 2.0 port
●500 datas can be stored

Main features
Can use various probe (F400, F1, F1/90 °, F10, N1, N400, etc.) measurement;
Three calibration methods: one point calibration, two point calibration, the basic calibration;
Display resolution: 0.1 um (measuring range of less than 100 um)
1μ m (range greater than 100 u m)
Have five statistics, data storage 500
There are two working methods: direct ways and means of group
There are two measurements: continuous measurement and a single measurement
There are two shutdown: manual and automatic shutdown shutdown
Can be set Bound: The gauge of the measured value can be automatic alarm and a number of measurements available on the histogram value analysis;
Deleted features: the gross error and error settings can be deleted;
Printing: Print Measurement measurement, statistics, gauges, histogram
A music tone in the operation carried out at any time tips
A power supply under-voltage direct function
An error function
And printers, computer communications (communications software operating environment for the Window operating system) connectivity.

Technical Specifications:

Measuring range

 

0-1250µ with standard probe F1.N1 (10.000mm    max)
Probes available

 

5 probes available for F (ferrous: on steel/iron) and N (non-ferrous metals)
Tolerance

 

F1:±(1µ+3%H) N1.±(1.5µ+3% H)

H: actual thickness tested

Resolution Alphanumeric with 4 large digits
Operation language English
Standards DIN, ISO, ASTM,BS
Min. measuring area F1:(standard probe)
Min. curvature  radius convex:3mm, concave:50mm
Min. substrate

thickness

type F: 0.5mm, type N: 50mm
Calibration Zero and foil calibration
Statistics

 

Number of measurements, mean, standard deviation,

maximum and minimum of 3000readings

Data memory 500  measuring data
Limits Adjustable with acoustic alarm
Interface USB 2.0
Operating temperature 0-40℃
power supply AA size 1.5V
Dimensions 125*67*31mm (main unit)
Weight 345.g

Standard Delivery

·  Main unit 1
·  Probe F1 or N1 1
·  Calibration foils 5
·  Instruction manual 1
·   Cetificate 1
·  Warranty card 1
·  Carrying case 1
Communication cable 1
PC software Dataview 1

Optional accessories
●5 probes for different applications
●Calibration foils in various thickness

ery (1)

Type F probe:

Probe

F400

F5

F1

F1/90°

F10

Measuring Principle   Magnetic method
Measuring range(mm)

0400um

01250 um

010000

Min resolution(mm)

0.1

0.1

10

Tolerance One-point calibration (mm)

±(2%H+0.7)

±(2%H+1)

±(2%H+10)

Two-point calibration (mm) ±(1%H+0.7)

±((1%H+1)

±(1%H+10)

Minimum radius of curvature (convex) (mm)

1

1.5

1.5

flat

10

 Minimum measuring area(mm)

F3

F7

F7

F40

Minimum thickness of base material(mm)

0.2

0.5

0.5

2

Type N probe

Probe N400

N1

CN02

Measuring Principle

Eddy current method

 Measuring range (mm)

0400

01250

10200

 Min resolution(mm)

0.1

0.1

1

Tolerance  One-point calibration (mm)

±(2%H+0.7)

±(2%H+1.5)

±(2%H+1)

 Two-point calibration (mm) ±(1%H+0.7) ±1%H+1.5

——–

Minimum radius of curvature (convex) (mm)

1.5

3

flat

Minimum measuring area(mm)

F4

F5

F7

Minimum thickness of base material(mm)

0.3

0.3

0


Product detail pictures:

OEM Supply Paint Coating Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck detail pictures


Related Product Guide:

Sticking towards the theory of "Super Good quality, Satisfactory service" ,We are striving to become a superb business enterprise partner of you for OEM Supply Paint Coating Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck , The product will supply to all over the world, such as: Southampton, French, Irish, If you are for any reason unsure which product to select, do not hesitate to contact us and we are going to be delighted to advise and assist you. This way we are going to be providing you with all the knowledge needed to make the best choice. Our company strictly follows "Survive by good quality, Develop by keeping good credit. " operation policy. Welcome all the clients old and new to visit our company and talk about the business. We have been looking for more and more customers to create the glorious future.
  • The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Doris from Swansea - 2017.12.02 14:11
    The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Claire from Tajikistan - 2017.08.18 11:04
    Write your message here and send it to us