Ultrasonic Flaw Detector TFD900 (working steadily in strong magnetic environment)
The TFD900 is an ultra-light handy UT instrument of outstanding performance. Compatible with EN12668-1:2010,
This instrument is mounted with TG TFT display of full WVGA (800×480) resolution for excelling visibility even used outdoors or in strong sunlight. Another amazing feature of this product is the “square wave drive” which realizes the user’s dream for best sensitivity and resolution. Moreover, it’s compatible with EN12668-1:2010, the popular instrumentation standards widely recognized in European and even the international market. Weighing only 0.9kg, this apparatus enables the user to carry it just like an on-hand tool for instant inspection task. All these distinct advantages make it superior as compared to its counterparts.
Highlights of TFD900
☆ Curved Surface Consideration
☆ DGS & DAC functional Curve
☆ RF Waveforming Mode
☆ Recording (1 Hour in Total)
☆ Echo Crest Tracking
☆ Enveloping (for Waveform Comparison)
☆ AWS D1.1 Evaluation Module
☆ API 5UE Evaluation Module
☆ Performance Indices Test
☆ 1000 Frames of A-scan Storage
☆ ComApp for PC Review and Report Print
☆ 0.9kg in Weight
Features:
·Circuitry of advanced design and sampling frequency up to 640MHz ensure instant and accurate display and analysis of flaw signals even when they’re weak.
·State-of-the-art square wave drive technique
·Weighing only 0.9kg, convenient for operation and taking it along
·TG, full WVGA TFT display
·8+ hour battery life promises consecutive working, inbuilt smart-type battery charger, auto-switching between the status of charging and that of powering.
·External USB port for software upgrading, data transferring and printing, graftable to mouse,
keyboard and USB disc.
·EN12668:2000 compatible
Specification
Attenuator Error | Per 12dB ±1dB |
Equivalent Input Noise | <80×10-9 V/√HZ^ |
Pulse Type | -ve square wave, Tv: 25~250V ; tunable with 25V per step |
Working Modes | T\R ; T&R |
Damping | 400\80 Ohm |
Working Frequency | W\N Band, W: 0.5~20MHz; N: 1.5~3MHz |
Gain | 0.0~110.0dB; 0.1\1.0\2.0\6.0 dB per step; smart speed-up at 0.1dB |
Material Velocity | 1000~15000m/s tunable; preset 30 frequently-used Vs optional |
Display Reachable | 0.0~10000mm LW at steel velocity tunable with min 0.1mm perstep |
Rectification | Positive, Negative, Full, RF (1002plus) |
Gate & Alarm | Dual gates, hardware driving real-time alarming;Alarming condition: excess\loss\ DAC; Alarm mode: sound ; |
Spotting: peak | |
Display | TG, TFT 5.6 inch WVGA color display, resolution 800×480 |
Pulse Shift Range | -7.5~3000μs |
Probe Delay Available | 0~999.9μs |
PRF | 25~800Hz, auto adaptation |
Vertical Linearity Error | ≤3% |
Horizontal Linearity Error | ≤0.2% |
Sensitivity Surplus | ≥60dB (200Φ2 FBH) |
Discernibility | ≥36dB (mated with 5MHzΦ14 transducer) |
Dynamic Range | ≥32dB |
Rejection | (0~90) %, without any dent to linearity or gain |
NL | <10% |
Ports | BNC probe connector |
USB HOST | |
Power Supply | Large-capacity Li battery without memory effect; battery life: 8+hrs; |
In-built battery charger (independent charger optional); AC: 220V | |
Dust\Splash\Water Proof | IP54 |
UT Standards | Compatible with EN12668-1 |
Meets JB/T 10061-1999 | |
Ambient Temperature | -30~50℃ |
Relative Humidity | 20%~95% |
Weight | Around 0.9kg (with battery & in-built charger) |
Dimension | Upper Part: 215mm×126mm×53mm |
Lower Part: 215mm×104mm×42mm |